CAB les 3: Toilet & Oven fire

Cabine les: Toilet and oven fire
1 / 28
volgende
Slide 1: Tekstslide
CabineMBOStudiejaar 2

In deze les zitten 28 slides, met interactieve quizzen, tekstslides en 3 videos.

time-iconLesduur is: 45 min

Onderdelen in deze les

Cabine les: Toilet and oven fire

Slide 1 - Tekstslide

Inhoud les
Kennis quiz halon & water
Pre-flight check list fire fighting equipment
Toilet fire
Oven fire

Slide 2 - Tekstslide

The waterfire extinguisher may be used on...
A
Electrical fires
B
Fires concerning dangerous goods
C
Burning fluids
D
Seats / luggage

Slide 3 - Quizvraag

What is the discharge time of the water fire extinguisher?
A
+/- 20 seconds
B
+/- 30 seconds

Slide 4 - Quizvraag

Which component is missing in the fire triangle?
A
Wood
B
Fire
C
Air
D
Heat

Slide 5 - Quizvraag

What is the discharge time of the halon fire extinguisher?
A
+/- 15 seconds
B
+/- 10 seconds

Slide 6 - Quizvraag

Halon does cool the material.
A
True
B
False

Slide 7 - Quizvraag

Pre-flight checklist
Fire fighting equipment

Slide 8 - Tekstslide

Water fire extinguisher
- Sealed
- Correctly stowed

Slide 9 - Tekstslide

Halon fire extinguisher
- Safety pin in place
- Neelde in green band
- Correctly stowed

Slide 10 - Tekstslide

PBE
- Sealed
- Correctly stowed

Slide 11 - Tekstslide

Axe
- Correctly stowed

Slide 12 - Tekstslide

Fire proof gloves
- Correctly stowed

Slide 13 - Tekstslide

Slide 14 - Video

Fire fighting procedures 
Toilet & Oven fire

Slide 15 - Tekstslide

Toilet fire

Slide 16 - Tekstslide

Fire in lavatory: CA?
- Smoke detector panel: check which toilet
- Press horn interrupt switch
- Announce applicable lavatory via PA

Slide 17 - Tekstslide

Fire extinguishing system
- Located beneath the sink in each lavatory
- Nozzle discharge toward waste disposal container
- Temperature indicator located inside the waste compartment

Slide 18 - Tekstslide

Slide 19 - Video

Standard procedure lavatory CA:
- Fetch HAL (halon)
- Check lavatory handle for temperature with back of hand
- Open lavatory door slightly if door handle is tolerably warm
- Stay low behind door and empty extinguisher 'around the corner'
- Close door
- Inform flight crew and fetch additional equipment

Slide 20 - Tekstslide

Prodecure lavatory
1. Fetch Halon
2. Check lavatory door handle temperature
3. Open lavatory slightly
4. Stay low behind door & empty extinguisher
5. Inform FC + additional equipment

Slide 21 - Tekstslide

Standard procedure with another CA arrive with PBE/HAL/H20/AXE/FPG you:
- Locate the source of the fire and inspect it
- Turn the gasper fan off (if installed)
- Cool any fire residue
- Check for re-ignition
- Reset on smoke detector panel
- Inform flight crew when fire is extinguished completely

Slide 22 - Tekstslide

IMPORTANT:
FIGHT FIRE FIRST!

Slide 23 - Tekstslide

Oven fire

Slide 24 - Tekstslide

Slide 25 - Video

Standard prodecure OVEN fire
- (Shut oven door)
- Switch of electrical power
- Fetch Halon
- Open door slightlly, extinguish shortly 'around the corner' and shut door
- Inform FC and fetch additional equipment
- Wait about 2 minutes before opening door

Slide 26 - Tekstslide

When anotother CA arrive with equipment
- Check fire is extinguished completely
-Smouldering residue shall be cooled with water outside oven
- Check for re-ignition
- Inform FC when fire is extinguished completely

Slide 27 - Tekstslide

IMPORTANT
FIGHT FIRE FIRST!

Slide 28 - Tekstslide