In deze les zitten 25 slides, met interactieve quizzen en tekstslides.
Onderdelen in deze les
Revision Mock 2
Slide 1 - Tekstslide
1. This test is designed to assess current knowledge in gas safety only.
2. Reference material is permitted.
3. Regulations referred to in this assessment paper mean, the Gas Safety (Installation & Use) Regulations 1998.
Slide 2 - Tekstslide
The Gas Safety (Installation & Use) Regulations, defines an ‘Appropriate Fitting’ as being: -
A
Tees and Elbows
B
Copper Tube
C
A fitting that is used to make a gas tight seal
D
Mild Steel
Slide 3 - Quizvraag
The Gas Safety (Installation & Use) Regulations apply to any gas fitting used in connection with: -
A
Gas conveyed to a dwelling through a distribution main only.
B
Gas conveyed from a storage vessel only.
C
Gas conveyed to a dwelling through a distribution main or from a storage vessel.
D
Gas supplied through a distribution main to pressurise a storage vessel only.
Slide 4 - Quizvraag
Which of the following installations ARE covered by The Gas Safety (Installation & Use) Regulations: -
A
Natural Gas powered Cars.
B
Natural Gas powered Fork Lift Truck.
C
Natural Gas powered Bus.
D
Hired holiday houseboat connected to a metered Natural Gas supply.
Slide 5 - Quizvraag
From the following list, indicate what installations ARE NOT covered by The Gas Safety (Installation & Use) Regulations: -
A
Gas fittings used in a training or assessment centre.
B
Gas fittings used in a dwelling.
C
Gas fittings used in a houseboat.
D
Gas fittings used in rented accommodation.
Slide 6 - Quizvraag
The Gas Safety (Installation & Use) Regulations specifically state, ‘no person shall carry out work in relation to a gas fitting unless they are’: -
A
A Plumber.
B
A Gas Fitter.
C
Competent to do so.
D
A Pipe Fitter.
Slide 7 - Quizvraag
Where an installer, who is working on the existing gas supplies, leaves the property for more material, he/she must ensure: -
A
A temporary continuity bond is left in place.
B
An ‘At Risk’ notice is displayed
C
A work in progress notice is displayed.
D
All open ends of the pipe work are sealed.
Slide 8 - Quizvraag
Where work is carried out, on a gas supply, that may effect the gas tightness of the installation, on completion of the work the installation must be immediately: -
A
Vented
B
Purged
C
Serviced
D
Soundness tested
Slide 9 - Quizvraag
Where a gas supply is likely to be exposed to any harmful or corrosive substances, it must be suitably protected with: -
A
Corrosion resistant material.
B
Water resistant material.
C
Lead Alloy.
D
Mild Steel.
Slide 10 - Quizvraag
A second hand appliance can only be installed if it: -
A
Has been suitably modified.
B
Is verified to be in safe condition.
C
Comes with a guarantee of purchase.
D
Has a modern flame supervision device fitted.
Slide 11 - Quizvraag
Can the flame supervision device found in an oven be wedged open, to allow the consumer to continue using the appliance?: -
A
Only with the customers permission.
B
Only if burner rating in the oven is less than 7kW.
C
Only where the customer agrees a future date for the replacement part to be fitted.
D
This is not allowed.
Slide 12 - Quizvraag
Where CORGI decide to remove an installer from the Gas Safe register they must:-
A
Give a years notice.
B
Phone and tell the installer they are removed from the list.
C
Send an inspector to tell them.
D
Give notice of withdrawal of such approval in writing.
Slide 13 - Quizvraag
From the following list, a safety inspection on an appliance for a Landlord, should include: -
A
The flue, ventilation, burner pressure and its safe functioning.
B
The flue and ventilation only.
C
Ventilation only.
D
The appliance efficiency only.
Slide 14 - Quizvraag
A net rated appliance burns 0.040 m3 of gas in 2 minutes. What is its gas rate?
A
14.3kw
B
11.6kw
C
13.3kw
D
4kw
Slide 15 - Quizvraag
A gross appliance using an imperial meter takes 1 minute and 22 seconds to complete a revolution. What is its gas rate?
A
11.8kw
B
12.3kw
C
13.4kw
D
14.7kw
Slide 16 - Quizvraag
When you carry out a gas rate on an oven, you do so with the oven door…
A
Open
B
Closed
Slide 17 - Quizvraag
A ventilation brick has an effective area of 45cm2. What size of net open flued appliance will it be suitable for?
A
13kw
B
14kw
C
15kw
D
16kw
Slide 18 - Quizvraag
The meter volume of a U6 meter is
A
0.0024
B
0.008
C
0.025
D
0.01
Slide 19 - Quizvraag
The minimum support interval for 22mm mild steel pipe running horizontally is
A
2.5m
B
3.0m
C
2.7m
D
2m
Slide 20 - Quizvraag
An open flued appliance of 12kw net is placed in a compartment which has ventilation air directly from outside. What LOW LEVEL ventilation is required?
A
25 cm2
B
110 cm2
C
60 cm2
D
120 cm2
Slide 21 - Quizvraag
Which of the following items in a room would affect the outcome of a spillage test?
A
Radiant electric fire
B
Ceiling Fan
C
Intumescent Air Vent
D
Poorly notched joist
Slide 22 - Quizvraag
A room sealed fan draught appliance terminal should be no closer below a gutter than
A
75mm
B
300mm
C
600mm
D
1200mm
Slide 23 - Quizvraag
A number of circumstances can lead to flue reversal. Which of the following is NOT one of them?
A
Heat loss in the secondary flue
B
Incorrect terminal location
C
Poorly maintained enamel covering
D
Climatic Conditions
Slide 24 - Quizvraag
When using a gas cooker to test the meter governor working pressure it must be set to