22. Flue Construction 1

Flue Construction 1
1 / 50
volgende
Slide 1: Tekstslide
FluesHigher Education (degree)

In deze les zitten 50 slides, met interactieve quizzen en tekstslides.

Onderdelen in deze les

Flue Construction 1

Slide 1 - Tekstslide

Slide 2 - Tekstslide

Slide 3 - Tekstslide

Which chemical present in the products of combustion makes it necessary the have materials that are resistant to mild acid
A
Nitrogen
B
Water
C
CO2
D
CO

Slide 4 - Quizvraag

Slide 5 - Tekstslide

Slide 6 - Tekstslide

Slide 7 - Tekstslide

Slide 8 - Tekstslide

Slide 9 - Tekstslide

Slide 10 - Tekstslide

Slide 11 - Tekstslide

Above what size is an approved terminal not required
A
170mm
B
100mm
C
50mm
D
25mm

Slide 12 - Quizvraag

Slide 13 - Tekstslide

Slide 14 - Tekstslide

Why must flue liners be fully sealed at the bottom?
A
It looks neat
B
The liner is porous and leaks into the chimney
C
It helps flue flow
D
It retains heat

Slide 15 - Quizvraag

Slide 16 - Tekstslide

Why do external flues require lining at shorter lengths than internal flues
A
The effect of sunlight
B
They tend to be colder and less efficient
C
They tend to be warmer and less efficient
D
It is more expensive to line external flues

Slide 17 - Quizvraag

Slide 18 - Tekstslide

Slide 19 - Tekstslide

Slide 20 - Tekstslide

Slide 21 - Tekstslide

Slide 22 - Tekstslide

Slide 23 - Tekstslide

Slide 24 - Tekstslide

What is the minimum csa for a circular flue
A
12000mm
B
16500mm
C
125mm
D
1500mm

Slide 25 - Quizvraag

Slide 26 - Tekstslide

Slide 27 - Tekstslide

What is the minimum cross sectional area of a rectangular pre cast flue block made in 1995
A
16500mm
B
125mm
C
170mm
D
100mm

Slide 28 - Quizvraag

Slide 29 - Tekstslide

Slide 30 - Tekstslide

Slide 31 - Tekstslide

You attend a block of flats to repair a boiler. On the way in you notice that there are labelled ventilation grilles at groung floor level.
What type of ventilation system would you expect?
A
SE Duct
B
U Duct

Slide 32 - Quizvraag

Slide 33 - Tekstslide

Twin-walled flues using only air as an insulator and fitted to the exterior of a house must not exceed what length
A
1m
B
3m
C
5m
D
This is not allowed

Slide 34 - Quizvraag

Slide 35 - Tekstslide

Slide 36 - Tekstslide

Slide 37 - Tekstslide

Slide 38 - Tekstslide

Slide 39 - Tekstslide

Slide 40 - Tekstslide

Slide 41 - Tekstslide

Slide 42 - Tekstslide

Slide 43 - Tekstslide

Slide 44 - Tekstslide

Slide 45 - Tekstslide

Slide 46 - Tekstslide

When placing a vertical flue which requires a bend, the law requires that the flue must run straight for the first
A
600mm
B
50mm
C
120mm
D
170mm

Slide 47 - Quizvraag

Slide 48 - Tekstslide

Slide 49 - Tekstslide

Flues that cannot be placed on external walls and must be run through attic areas are generally called
A
Open Flue
B
Room Sealed
C
Horizontal Flue
D
Vertex Flue

Slide 50 - Quizvraag